<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ε.Σ.Σ.Α.Η.Ε</title>
	<atom:link href="https://haess.gr/en/feed/" rel="self" type="application/rss+xml" />
	<link>https://haess.gr/en/</link>
	<description>Ελληνικός Σύνδεσμος Συστημάτων Αποθήκευσης Ηλεκτρικής Ενέργειας</description>
	<lastBuildDate>Tue, 24 Nov 2026 08:08:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://haess.gr/wp-content/uploads/2026/11/haess-company-essahe-pin-150x150.png</url>
	<title>Ε.Σ.Σ.Α.Η.Ε</title>
	<link>https://haess.gr/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How storage plants participate in the Greek electricity market</title>
		<link>https://haess.gr/en/how-storage-plants-participate-in-the-greek-electricity-market/</link>
		
		<dc:creator><![CDATA[Ε.Σ.Σ.Α.Η.Ε]]></dc:creator>
		<pubDate>Thu, 19 Nov 2026 07:51:00 +0000</pubDate>
				<category><![CDATA[News]]></category>
		<guid isPermaLink="false">https://haess.gr/?p=823</guid>

					<description><![CDATA[<p>From trial operation to commercial operation Commissioning tests and trial operation. Before a storage entity can enter commissioning tests or trial operation, the technical decisions of the Independent Power Transmission Operator (IPTO) require it to be preregistered in IPTO’s Register of Dispatchable Storage Entities. Once the plant is energised, checks cover its grid connection, power [&#8230;]</p>
<p>Το άρθρο <a href="https://haess.gr/en/how-storage-plants-participate-in-the-greek-electricity-market/">How storage plants participate in the Greek electricity market</a> εμφανίστηκε πρώτα στο <a href="https://haess.gr/en/">Ε.Σ.Σ.Α.Η.Ε</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>From trial operation to commercial operation</strong></p>



<p class="wp-block-paragraph"><strong>Commissioning tests and trial operation.</strong> Before a storage entity can enter commissioning tests or trial operation, the technical decisions of the Independent Power Transmission Operator (IPTO) require it to be preregistered in IPTO’s Register of Dispatchable Storage Entities. Once the plant is energised, checks cover its grid connection, power measurements and the communications it uses to receive and execute dispatch instructions. Depending on the service, these checks cover the remote terminal unit (RTU) link to IPTO’s automatic generation control (AGC) system or the web services link to its Balancing Market platform.</p>



<p class="wp-block-paragraph">For commissioning tests and for trial operation lasting more than four hours, IPTO submits the scheduled purchases or sales to the Day-Ahead Market of the Hellenic Energy Exchange (HEnEx) as priority price-taking (PPT) orders. Once a plant covered by this procedure has passed the required checks, the relevant system operator issues a certificate confirming completion of trial operation.</p>



<p class="wp-block-paragraph"><strong>Who represents a storage plant at HEnEx and IPTO?</strong></p>



<p class="wp-block-paragraph">On the HEnEx Day-Ahead and Intraday Markets, buy and sell orders may be submitted by the plant owner, if registered as a market participant, or by an aggregator authorised to represent storage plants. Either may represent a large storage plant individually or represent a storage portfolio. Under the <a href="https://www.admie.gr/agora/rythmistiko-plaisio-agoras/kanonismos-agoras-eksisorropisis" target="_blank" rel="noreferrer noopener">Balancing Market Rulebook</a>, a storage plant is classified as large if it is connected to the Hellenic Electricity Transmission System and has a maximum injection capacity of <strong>10 MW or more</strong>.</p>



<p class="wp-block-paragraph"><strong>A balancing service provider (BSP)</strong> is a market participant with balancing service entities at its disposal through which it can provide balancing services to IPTO. The BSP registers with IPTO, enters into a contract with it and submits bids for balancing capacity or balancing energy. A balancing service entity is the unit or portfolio technically capable of delivering the service. Prequalification establishes which services each entity can provide. A BSP may represent several entities. Bids and dispatch instructions are separate for each one.</p>



<p class="wp-block-paragraph"><strong>The balance responsible party (BRP) </strong>is financially responsible for imbalances. A licence holder that represents its own dispatchable storage plant must register with IPTO in the relevant capacities. If the holder delegates representation, the aggregator it appoints must be authorised to represent storage plants and registered as both a BSP and a BRP. The aggregator notifies IPTO of its agreement with the holder and identifies the entity and its meters. The holder may retain technical control of the plant.<br>Under the transitional provisions of Law 5287/2026, existing renewable energy or demand response aggregators covered by the law may register by submitting their licence and proof that they have applied to extend it to storage.</p>



<p class="wp-block-paragraph"><strong>Capacity limit per person or corporate group. </strong>Through the end of 2029, Law 5299/2026 sets a <strong>500 MW</strong> limit on the combined maximum injection capacity of battery storage plants within its scope. The calculation takes account of ownership, the revenue assignment agreements specified in the law and representation, including the interests of linked or partner enterprises. The exemptions in Article 10(11A) of Law 4685/2020 and Article 50B(8) of Law 4951/2022 apply.</p>



<p class="wp-block-paragraph"><strong>Which HEnEx products are open to storage plants?</strong></p>



<p class="wp-block-paragraph"><a href="https://www.enexgroup.gr/documents/20126/211889/Decision_RAAEY_%CE%95-38_2026_OrderTypes_EN.pdf" target="_blank" rel="noreferrer noopener">Decision E-38/2026</a> of the Regulatory Authority for Waste, Energy and Water (RAAEY) specifies the products and order types available to storage plants on the spot markets. In the markets for physical delivery, the owner or aggregator submits orders for the registered large storage plant or the relevant portfolio.</p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td><strong>Market</strong></td><td><strong>Products and order types available to storage plants</strong></td></tr><tr><td><strong>Day-Ahead Market (DAM) Single Day-Ahead Coupling (SDAC)</strong></td><td>Plants may submit 15-minute hybrid buy or sell curve orders with stepwise or linear segments, and block orders with 15-minute resolution. Hourly time-unit orders are unavailable to this category of participant.</td></tr><tr><td><strong>Intraday auctions IDA1, IDA2 and IDA3</strong></td><td>Plants may submit 15-minute hybrid curve orders in all three auctions. IDA1 and IDA2 cover the full delivery day. IDA3 covers its second half.</td></tr><tr><td><strong>Continuous intraday trading XBID</strong></td><td>Plants may trade 15-, 30- and 60-minute products. They may also define a block of 2 to 30 consecutive periods of equal duration, with the same price and quantity for each period. The block is executed in full. The order book accepts limit, linked and iceberg orders.</td></tr></tbody></table></figure>



<p class="wp-block-paragraph">In the Day-Ahead Market, a <strong>simple block order</strong> has the same acceptance ratio across all periods it covers. With linked block orders, acceptance of one order depends on acceptance of another. In an exclusive group of block orders, the sum of the acceptance ratios cannot exceed 100%. A circular block order links a buy order to a sell order, for example to pair midday charging with evening discharge. Both legs have the same acceptance ratio, but their volumes may differ to account for energy losses. Each entity may submit up to five block orders in total, including up to two circular pairs.</p>



<p class="wp-block-paragraph"><strong>Adjusting a position.</strong> In an intraday auction (IDA) or in continuous intraday trading (XBID), a buy order that is executed can reduce the volume a plant is due to deliver after a sale in the Day-Ahead Market or an earlier intraday auction for the same delivery day. Equally, a sale can reduce the volume the plant is due to withdraw following an earlier purchase. Its net position for the delivery period determines its scheduled injection or withdrawal.</p>



<p class="wp-block-paragraph"><strong>Example.</strong> A plant sells <strong>2 MWh</strong> in the Day-Ahead Market for 20:00–20:15, scheduling an injection of<strong> 8 MW</strong> for 15 minutes. If it buys back <strong>0.75 MWh</strong> in IDA1 for the same market time unit (MTU), its scheduled injection falls to <strong>1.25 MWh</strong>, or <strong>5 MW</strong> over the quarter-hour. Buying back the full <strong>2 MWh</strong> brings its net position to zero.</p>



<p class="wp-block-paragraph"><strong>Which balancing services can storage plants provide?</strong></p>



<p class="wp-block-paragraph">A storage plant participates in IPTO’s Balancing Market through its BSP. The plant owner or an authorised aggregator can take on this role.</p>



<p class="wp-block-paragraph">The Balancing Capacity Market has <strong>six capacity products</strong>, <strong>measured in MW</strong>. The Balancing Energy Market has <strong>four activation products</strong>, <strong>measured in MWh</strong>. A plant responds to an upward activation by increasing injection or reducing charging. It responds to a downward activation by reducing injection or increasing charging.</p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td><strong>IPTO reserve product</strong></td><td><strong>Capacity direction</strong></td><td><strong>Balancing energy</strong></td></tr><tr><td><strong>Frequency containment reserve (FCR)</strong></td><td>Upward and downward</td><td>No separate energy bid</td></tr><tr><td><strong>Automatic frequency restoration reserve (aFRR)</strong></td><td>Upward and downward</td><td>Upward and downward</td></tr><tr><td><strong>Manual frequency restoration reserve (mFRR)</strong></td><td>Upward and downward</td><td>Upward and downward</td></tr></tbody></table></figure>



<p class="wp-block-paragraph">In the Integrated Scheduling Process (ISP), capacity awards are added together separately for each direction. The totals must stay within the plant’s or portfolio’s declared injection and withdrawal limits. Participants declare and update those limits on IPTO’s Balancing Market platform.</p>



<p class="wp-block-paragraph"><strong>When a dispatchable storage plant is awarded aFRR or mFRR capacity, its BSP must offer the corresponding balancing energy for the same quarter-hour and in the same direction.</strong> The obligation to submit an energy bid begins during the ISP, when the BSP submits the corresponding capacity bid.</p>



<p class="wp-block-paragraph">Balancing energy products are settled on a pay-as-clear basis. Balancing capacity is settled on a pay-as-bid basis.</p>



<p class="wp-block-paragraph"><strong>The two project groups and how operating aid is calculated</strong></p>



<p class="wp-block-paragraph">Before a supported plant receives its operating licence, RAAEY assigns it to one of two project groups, based on the minimum guaranteed storage capacity required in the tender in which it was selected, expressed in MWh per MW. The group provides the benchmark for calculating operating aid. Market orders are submitted by the plant or the representative of its trading portfolio.</p>



<p class="wp-block-paragraph">Each group’s revenue calculation also includes unsupported plants that trade in the market (merchant storage), provided that the guaranteed capacity stated in their storage licence is within ±25% of the relevant tender minimum. Unsupported plants that participate through an aggregator’s portfolio are excluded from this comparison. A merchant plant is included solely for the purpose of calculating group revenue.</p>



<p class="wp-block-paragraph"><strong>Who estimates market revenue?</strong> The Renewable Energy Sources and Guarantees of Origin Operator (DAPEEP) prepares the estimate and submits its recommendation and supporting study to RAAEY. IPTO, HEnEx and the Hellenic Electricity Distribution Network Operator (HEDNO) supply the data for which each is responsible. RAAEY sets the final figure in euros per MW for each project group and each year of the regulatory period.</p>



<p class="wp-block-paragraph"><strong>How is aid calculated for each plant?</strong> The starting point is the plant’s reference revenue, set by its winning bid. The group’s estimated market revenue per MW is deducted from this figure, and the prescribed adjustments for additional revenue or losses are applied. Net revenue consists of receipts from electricity sales and balancing services after deducting costs such as electricity purchased for charging and market fees.</p>



<p class="wp-block-paragraph"><strong>How does market performance affect a plant’s revenue?</strong> At the annual review, the group’s total net revenue is divided by the sum of the participating capacities of its plants. If group membership changes during the year, the calculation is made separately for each period. As a rule, the adjustment to operating aid reflects 100% of the difference between the group’s forecast and actual revenue. All else being equal, a plant that earns more per MW than the group average therefore keeps the benefit of its better performance. If the calculation produces a negative aid payment, the amount is repaid or offset.</p>



<p class="wp-block-paragraph"><strong>First application in 2026.</strong> In Decision E-218/2026, RAAEY adopted the P75 scenario from DAPEEP’s study. Estimated market revenue was approximately <strong>€157,000/MW for a two-hour plant over the full 2026 calendar year</strong> and <strong>€101,000/MW for a four-hour plant in the second half of 2026</strong>. The two estimates cover different periods. The decision sets monthly aid separately for each plant according to the month in which its operating licence is issued.</p>
<p>Το άρθρο <a href="https://haess.gr/en/how-storage-plants-participate-in-the-greek-electricity-market/">How storage plants participate in the Greek electricity market</a> εμφανίστηκε πρώτα στο <a href="https://haess.gr/en/">Ε.Σ.Σ.Α.Η.Ε</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electricity storage at the heart of the energy transition</title>
		<link>https://haess.gr/en/electricity-storage-the-heart-of-the-energy-transition/</link>
		
		<dc:creator><![CDATA[Ε.Σ.Σ.Α.Η.Ε]]></dc:creator>
		<pubDate>Thu, 05 Jun 2025 08:00:00 +0000</pubDate>
				<category><![CDATA[Articles]]></category>
		<category><![CDATA[News]]></category>
		<guid isPermaLink="false">https://haess.gr/?p=549</guid>

					<description><![CDATA[<p>The transition to a greener, more sustainable future is one of Greece’s most important energy policy goals. It will give the country the resilience it needs as crises become more frequent and help it compete internationally as conditions change. Greece must therefore make the most of its own energy resources, including renewables such as solar [&#8230;]</p>
<p>Το άρθρο <a href="https://haess.gr/en/electricity-storage-the-heart-of-the-energy-transition/">Electricity storage at the heart of the energy transition</a> εμφανίστηκε πρώτα στο <a href="https://haess.gr/en/">Ε.Σ.Σ.Α.Η.Ε</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">The transition to a greener, more sustainable future is one of Greece’s most important energy policy goals. It will give the country the resilience it needs as crises become more frequent and help it compete internationally as conditions change.</p>



<p class="wp-block-paragraph">Greece must therefore make the most of its own energy resources, including renewables such as solar and wind. One encouraging sign is that in 2024 renewables, including large hydropower plants, accounted for 56% of the country’s electricity generation.</p>



<p class="wp-block-paragraph">As more electricity comes from renewables such as solar and wind farms, the national power system faces new demands. One of the most pressing is how to manage fluctuations in their output and the uncertainty over how much electricity they will produce.</p>



<p class="wp-block-paragraph">Electricity storage has a particular role here. It is the principal means of stabilising a power system that relies on intermittent sources.</p>



<p class="wp-block-paragraph">In 2024, Greece’s installed renewable generating capacity reached 13 GW. A further 16 GW of projects had secured grid connection offers and were awaiting connection. Applications still pending represented more than 40 GW, bringing the total to nearly 70 GW even before counting future projects still at the planning stage.</p>



<p class="wp-block-paragraph">Renewable generation already exceeds demand at certain times of day when consumption is low. This makes it harder to balance the system and can push electricity prices to zero or below. It also opens up opportunities for electricity storage systems to stabilise the grid and make fuller use of renewables, helping Greece move towards greener energy while maintaining the security and economic viability of its electricity supply.</p>



<p class="wp-block-paragraph">Electricity storage systems that can trade in the electricity markets therefore need to be built as soon as possible. They can smooth price swings over the course of the day, a particularly pressing issue, and help bring down the cost that consumers ultimately pay for electricity. Pairing storage with renewables will also allow us to manage the electricity generated more effectively, increase the share of renewables and keep the energy transition on a secure footing.</p>



<p class="wp-block-paragraph">The updated National Energy and Climate Plan (NECP) identifies adequate storage power and energy capacity as essential. By 2030 it envisages 4.3 GW of battery storage and 1.7 GW of pumped storage, a total of 6 GW.</p>



<p class="wp-block-paragraph">The licensing register of the Regulatory Authority for Waste, Energy and Water (RAAEY) shows that licensed electricity storage systems and hybrid projects combining renewables with storage already far exceed the NECP projections. Battery storage licences cover more than 40 GW of power and over 100 GWh of energy capacity. Pumped storage licences account for 5.26 GW and 50 GWh respectively. Licences for ‘special projects’ combining renewables and storage under Article 10(11B) of Law 4685/2020 add a further 6 GW of renewable generating capacity and 14 GWh of storage.</p>



<p class="wp-block-paragraph">Including licensed renewable projects in category 11A and hybrid projects on the islands brings the total to nearly 70 GW of storage power and 200 GWh of energy capacity. These figures show the strength of investor interest in electricity storage, encouraged by the sharp fall in the cost of lithium batteries and other storage technologies.</p>



<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="1024" height="486" src="https://haess.gr/wp-content/uploads/2025/06/Electricity-storage-at-the-heart-of-the-energy-transition-1024x486.png" alt="" class="wp-image-678" style="aspect-ratio:2.1070784667241513" srcset="https://haess.gr/wp-content/uploads/2025/06/Electricity-storage-at-the-heart-of-the-energy-transition-1024x486.png 1024w, https://haess.gr/wp-content/uploads/2025/06/Electricity-storage-at-the-heart-of-the-energy-transition-767x364.png 767w, https://haess.gr/wp-content/uploads/2025/06/Electricity-storage-at-the-heart-of-the-energy-transition-300x142.png 300w, https://haess.gr/wp-content/uploads/2025/06/Electricity-storage-at-the-heart-of-the-energy-transition.png 1265w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<p class="wp-block-paragraph"><strong>The legal and regulatory framework</strong></p>



<p class="wp-block-paragraph">Until recently, uncertainty about the Greek regulatory framework for storage deterred investment. Since 2022, however, considerable work has gone into clarifying the rules, and storage is now recognised as having a distinct role in the energy mix.</p>



<p class="wp-block-paragraph">Two years ago, in response to the shortage of electricity storage systems, the government scheduled three tenders to support the rapid installation of 1 GW of storage. The first two concluded in 2023 and the third only in early 2025. In response to strong investor interest, the Ministry of Environment and Energy also plans to auction 3.55 GW of grid connection capacity this year for stand-alone merchant battery systems. These projects would receive priority for grid connection offers, without state aid. Under the draft ministerial decision put out to public consultation in late February, 2.65 GW would be available for projects connecting to the Independent Power Transmission Operator’s grid and 900 MW for those connecting to the Hellenic Electricity Distribution Network Operator’s grid. Together with the 900 MW already allocated through the completed tenders, the planned call is intended to meet the NECP’s 2030 target of 4.3 GW of battery storage as soon as possible.</p>



<p class="wp-block-paragraph">At present, the only electricity storage systems operating in the Greek market are the older hydropower plants with pumping capability, with a combined installed capacity of around 700 MW. The latest information also suggests that the first new storage projects will enter service in the first half of 2026, later than originally expected in 2025. Meanwhile, rising curtailment of renewable generation and the appearance of zero prices in the day-ahead market suggest that the country’s power system has reached its limits. Both trends pose serious challenges for the immediate future.</p>



<p class="wp-block-paragraph"><strong><strong>Conclusion </strong></strong></p>



<p class="wp-block-paragraph">Considerable work has gone into regulatory reform and the introduction of clear operating rules for storage systems. Several issues still need to be resolved before the framework is complete.</p>



<p class="wp-block-paragraph">Electricity storage is a cornerstone of the energy transition in Greece and internationally. With the right combination of technology, political will and funding, Greece can become a leader in green energy in south-eastern Europe. The stakes are high, and the momentum is encouraging.</p>
<p>Το άρθρο <a href="https://haess.gr/en/electricity-storage-the-heart-of-the-energy-transition/">Electricity storage at the heart of the energy transition</a> εμφανίστηκε πρώτα στο <a href="https://haess.gr/en/">Ε.Σ.Σ.Α.Η.Ε</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Why do we need electricity storage?</title>
		<link>https://haess.gr/en/why-do-we-need-electricity-storage/</link>
		
		<dc:creator><![CDATA[Ε.Σ.Σ.Α.Η.Ε]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 16:23:00 +0000</pubDate>
				<category><![CDATA[Articles]]></category>
		<category><![CDATA[News]]></category>
		<guid isPermaLink="false">https://haess.gr/?p=558</guid>

					<description><![CDATA[<p>Greece is expanding renewable generation and adapting its infrastructure under the Paris Agreement, the EU’s Green Deal and Fit for 55 package, and its own National Energy and Climate Plan (NECP) and Climate Law. It aims to make renewables the mainstay of its energy mix, reduce its dependence on fossil fuels by 2030 and end [&#8230;]</p>
<p>Το άρθρο <a href="https://haess.gr/en/why-do-we-need-electricity-storage/">Why do we need electricity storage?</a> εμφανίστηκε πρώτα στο <a href="https://haess.gr/en/">Ε.Σ.Σ.Α.Η.Ε</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Greece is expanding renewable generation and adapting its infrastructure under the Paris Agreement, the EU’s Green Deal and Fit for 55 package, and its own National Energy and Climate Plan (NECP) and Climate Law. It aims to make renewables the mainstay of its energy mix, reduce its dependence on fossil fuels by 2030 and end it by 2050.</p>



<p class="wp-block-paragraph">The rapid growth of renewables also brings new technical requirements and poses technical and economic problems that need to be resolved promptly. Under present conditions, it is vital to develop systems that can store electricity generated from renewable sources and to give them a clear, reliable regulatory framework in which to operate.</p>



<p class="wp-block-paragraph">Why is it so urgent to integrate energy storage? The number of renewable energy projects operating or under development in Greece has become practically unmanageable. Around 13 GW of renewable capacity is already operating, and another 16 GW of projects with grid connection offers is waiting to come online. Applications from new renewable projects awaiting connection terms account for more than 40 GW. That takes the total to 69 GW, even before any projects that may be developed from now on are counted.</p>



<p class="wp-block-paragraph">The surplus of renewable electricity expected at particular times of day, together with the variability of renewable generation, poses major technical challenges for grid capacity and power balancing, as well as economic challenges when marginal electricity prices fall to zero. It also creates an opportunity to make storage central to balancing the system and to use it to support a transition to a greener energy mix that is both economically feasible and technically secure.</p>



<p class="wp-block-paragraph">The updated NECP, published for consultation on 22 August, identifies storage with sufficient power and energy capacity as a prerequisite for integrating more renewables into the country’s energy mix. Electricity storage plants will be able to displace conventional generation at peak times by storing electricity mainly around midday, when renewable output is high. Some of that electricity is already being curtailed, and the amount is set to grow exponentially.</p>



<p class="wp-block-paragraph">Stand-alone storage systems will participate in the electricity markets, helping to smooth price swings over the course of the day, a pressing problem at present, and to bring down the prices that consumers ultimately pay.</p>



<p class="wp-block-paragraph">Storage systems using batteries can also be paired with renewables. They allow a hybrid plant to make the best use of the electricity it generates and can help to lower electricity prices.</p>



<p class="wp-block-paragraph">The updated NECP ultimately envisages 4.3 GW of battery storage and 1.7 GW of pumped storage by 2030, giving a combined power capacity of 6 GW.</p>



<p class="wp-block-paragraph">The electricity storage systems and hybrid renewable projects with storage in the licensing register of the Regulatory Authority for Waste, Energy and Water (RAAEY) already represent several times the capacity envisaged in the NECP. Licences issued for battery storage cover more than 40 GW of power and over 100 GWh of energy storage capacity. Pumped storage licences account for 5.26 GW and 50 GWh. Licences for ‘special projects’, which combine storage with renewables under Article 10(11B) of Law 4685/2020, account for almost 6 GW of renewable generating capacity and 14 GWh of storage.</p>



<p class="wp-block-paragraph">Including licensed category 11A renewable projects and licensed hybrid projects on the islands brings total storage power to an impressive 68 GW (Figure 1) and energy capacity to 193 GWh (Figure 2). These figures confirm the strength of the interest seen over many years.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="1403" height="565" src="https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.1.png" alt="" class="wp-image-715" srcset="https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.1.png 1403w, https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.1-767x309.png 767w, https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.1-300x121.png 300w, https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.1-1024x412.png 1024w" sizes="(max-width: 1403px) 100vw, 1403px" /><figcaption class="wp-element-caption">Figure 1</figcaption></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="1403" height="565" src="https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.2.png" alt="" class="wp-image-716" srcset="https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.2.png 1403w, https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.2-300x121.png 300w, https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.2-767x309.png 767w, https://haess.gr/wp-content/uploads/2025/02/Why-do-we-need-electricity-storage.2-1024x412.png 1024w" sizes="(max-width: 1403px) 100vw, 1403px" /><figcaption class="wp-element-caption">Figure 2</figcaption></figure>



<p class="wp-block-paragraph">Yet the only storage plants operating in the domestic market today are the older hydroelectric plants with pumping capability, with a total installed capacity of around 700 MW. The Greek electricity system appears to have reached its limits. Increasing curtailment of renewable generation and zero or even negative wholesale prices in the day-ahead market are evidence of the difficulties this presents.</p>



<p class="wp-block-paragraph">The government should move Greece as quickly as possible towards the energy transition and genuine energy independence. One important milestone for electricity storage in Greece was the support scheme for stand-alone battery systems. Under Law 4951/2022, the Greek government set in motion three auctions to support large-scale batteries with a combined capacity of 1 GW. The third and final auction is still pending. It covers 300 MW with a minimum duration of four hours, equivalent to 1,200 MWh of storage capacity.</p>



<p class="wp-block-paragraph">Complex technical, economic, social and political decisions still have to be made under considerable time pressure. The following steps are needed.</p>



<ul class="wp-block-list">
<li>Complete the regulatory framework as a matter of urgency, setting out how storage plants can participate in the relevant markets, particularly the balancing market, and what rules govern their participation. The last public discussion of market rules for electricity storage systems took place during the Independent Power Transmission Operator’s (IPTO) public consultation in April 2023. Since then, two auctions have awarded operating and investment aid to plants totalling 700 MW, yet the rules have progressed no further. With the first storage plants expected to enter operation in 2025, the main details of market participation must be settled as soon as possible through meaningful consultation with market participants.</li>



<li>Finalise and publish the methodology for annual support for electricity storage systems. It should clarify how and when compensation is settled, how long the regulatory period lasts and how projects are grouped, and resolve the other outstanding questions.</li>



<li>Remove the provision for imposing static operating restrictions on storage plants. The technology is inherently capable of responding dynamically and with considerable flexibility in the electricity markets.</li>



<li>Launch the third and final auction for storage plants with a four-hour storage requirement. Although the Greek electricity market has changed rapidly over the past three to four years, its storage market is still in its infancy. This makes regulatory certainty particularly important for investment support schemes that have already been approved and set in motion. Completing the current scheme must in no way prevent or delay the issue of connection terms to plants that wish to participate freely in the relevant markets. Renewable generators already have both options: they can participate in a support scheme or enter the market without aid.</li>



<li>Begin introducing a mechanism to remunerate available capacity as soon as possible and establish the competitive procedures it will require.</li>



<li>As part of its efforts to promote storage for system balancing, the government should also support storage facilities that can draw electricity from and inject it into the grid and that are paired with renewable generators, under Article 10(11B) of Law 4685/2020.</li>
</ul>



<p class="wp-block-paragraph">Greece is right to meet as much of its energy demand as possible from renewables. It aims to reduce its environmental footprint substantially and make its energy sector more competitive. Electricity storage systems can and should play a decisive role by enabling the country to integrate renewables safely and efficiently and build a resilient, sustainable energy future. We cannot afford to lose any more time.</p>
<p>Το άρθρο <a href="https://haess.gr/en/why-do-we-need-electricity-storage/">Why do we need electricity storage?</a> εμφανίστηκε πρώτα στο <a href="https://haess.gr/en/">Ε.Σ.Σ.Α.Η.Ε</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
